Description
The Patient Monitors YR02170 // YR02171 // YR02172 provide cutting-edge monitoring for patients with their advanced multi-channel display and user-friendly big font interface, facilitating easy readability. These monitors excel in medical settings due to their capabilities, including ST and arrhythmia analysis, drug dose calculations, and a dynamic OxyCRG view display. Additionally, they come equipped with essential features like apnea alarms for respiratory monitoring, a thorough alarm review system, and NIBP overpressure protection. These versatile monitors support both rechargeable battery use and AC/DC operation, with seamless wired or wireless network integration.
Market Price
The Patient Monitors YR02170 series typically range between 73500 USD and 74600 USD. Although prices vary based on features and suppliers, an accurate and competitive quote is always available at Kalstein Plus, where personalized deals can be tailored to your needs.
Frequently Asked Questions
Q: What connectivity options do these monitors offer?
A: These monitors provide flexible connectivity with both wired and wireless network support.
Q: Are these monitors able to operate on battery power?
A: Absolutely, the monitors offer options for plug-in rechargeable batteries in addition to AC/DC operation.
Advantages and Disadvantages
Advantages: High precision and resolution, flexible networking capabilities, and robust alarm systems for improved patient safety.
Disadvantages: The extensive features might necessitate additional training for optimal utilization.
Field Usage
The Patient Monitors of the YR02170 series are indispensable in hospitals and clinics, addressing a wide spectrum of patient monitoring requirements, from ECGs to vital signs and arrhythmia management. Suitable for adult, pediatric, and neonatal care, these monitors provide reliable, real-time monitoring in critical care settings.
Recommendations
To ensure optimal performance, regularly charge the batteries and keep the software updated for smooth network connectivity. It’s crucial to familiarize all users with the alarm settings and troubleshooting steps to enhance safety and efficiency. For more information on the monitor’s capabilities and integration potential, request a quote on Kalstein Plus today to secure the best possible deals.
Features
- Multi-channel display
- Big font interface
- ST and arrhythmia analysis
- Drug dose calculation and titration table
- OxyCRG dynamic view display
- Respiration monitoring with apnea alarms
- Alarm and arrhythmia review
- NIBP overpressure protection
- Rechargeable battery, AC/DC compatibility
- Wired or wireless networking support
Technical Specifications
Model | YR02170 | YR02171 | YR02172 | |
ECG | Lead mode | 5 Leads(RA,LA,LL,RL,V) | ||
Connection method | I, II, III,AVR,AVL,AVF,V | |||
Lead Mode | 3 Leads (RA,LA,LL) | |||
Connection method | I, II,III | |||
Waveform | 1ch | |||
Gain | x250, x500, x1000, x2000 | |||
HR Range | Adult: 15~300bpm | |||
Neo/Ped | 15~350bpm | |||
Accuracy | ±1% or ±1bpm | |||
Resolution | 1bpm | |||
Sensitivity | >200(uVp-p) | |||
Differential input impedance | ≥5MΩ | |||
ST segment Monitoring Range | ||||
Measure Range | -2.0~+2.0mV | |||
Measure Accuracy | -0.8mV~+0.8mV | |||
Heart Rate | Measuring range | 0~350bpm | 20~300bpm | |
Accuracy | ±1bpm | |||
Resolution | 1bpm | |||
Sensitivity | >200UVp-p | |||
Respiration | Method | Impedance between R-F(RA-LL) | ||
Differential Input Impedance | >2.5MΩ | |||
Measuring Impedance Range | 0.3~3.0 MΩ | |||
Base line Impedance Range | 200~4000Ω | |||
Bandwidth | 0.1~2.5Hz | |||
Resp. Rate | Adult: 2~120BrPM | |||
Neo/Ped | 2~150BrPM | 0~150BrPM | ||
Resolution | 1 BrPM | |||
Accuracy | ±2 BrPM | |||
Alarm | 10~40S | |||
NIBP | Method | Oscillometric | ||
Mode | Manual/Auto/STAT | |||
Measuring Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min) | |||
Measuring Period in STAT Mode | 5 Min | |||
Pulse Rate Range | 40~240bpm | |||
Alarm Type | SYS, DIA, MEAN | |||
Resolution | ||||
Pressure | 1mmHg | |||
Accuracy | Maximum Mean error: 5mmHg | |||
Maximum Standard deviation | 8mmHg | |||
SPO2 | Display | Number of SPO2,waveform of capacity,Pulse | ||
Measuring range | 0~100% | |||
Resolution | 1% | |||
Accuracy | 70~100% (±2%) | |||
Alarm system | Audio-video alarm | |||
Pulse rate range | 0~300bpm | |||
TEMP | Channel | 2 | ||
Measuring and Alarm Range | 0~50ºC | |||
Resolution | 0.1ºC | |||
Accuracy | 0.1ºC | |||
Actualization interval | about 1 Second. | |||
Average Time Constant | <10 Second. |