fbpx

Electrolyte Analyzer YR06407// YR06417

Manufacturer: Kalstein

Description

  • This device features a human-machine interactive menu with dynamic, real-time display of sample IDs. It includes automatic liquid level detection and alarms, along with real-time diagnostics of system status. It efficiently detects and filters tiny bubbles to prevent clogs and ensure precise measurements. The wave theory flushing method and direct flushing pipe method help avoid blockages and cross-contamination.
  • The instrument performs automatic calibration and two-point correction, offering print-outs of QC graphs and statistical parameters. Power failure protection prevents data loss, and the device supports fuzzy queries, LIS software, and selectable data upload formats. It also supports RTC clock management and can be powered off anytime to reduce reagent consumption, making it suitable for various hospitals.
Technical specifications
Model YR06407 YR06408 YR06409 YR06410 YR06411
Sample serum, plasma, whole blood and dilute urine
Storage up to 10000 test results
Printer Internal thermal printer
Interface RS232 port
Analysis Method ion selective electrode (ISE)
Measuring speed <30s
Sample position 39 positions (including 5 emergency and 4 functional positions)
Temperature 5-40°C
Relative Humidity <80%
Atmospheric pressure 86~106 kPa
Power supply AC220V±22V, 50Hz±1Hz
Power <120W
Test Parameters K Na Cl K Na Cl TCO AG K Na Cl iCa nCa TCa pH K Na Cl iCa nCa TCa pH TCO AG K Na Cl Li

 

Model YR06412 YR06413 YR06414 YR06415 YR06416 YR06417
Sample serum, plasma, whole blood and dilute urine
Storage up to 10000 test results
Printer Internal thermal printer
Interface RS232 port
Analysis Method ion selective electrode (ISE)
Measuring speed <30s
Sample position 39 positions (including 5 emergency and 4 functional positions)
Temperature 5-40°C
Relative Humidity <80%
Atmospheric pressure 86~106 kPa
Power supply AC220V±22V, 50Hz±1Hz
Power <120W
Test Parameters K Na Cl iCa nCa TCa pH Li K Na Cl iCa nCa TCa pH Li TCO AG K Na Cl iCa nCa TCa pH Mg K Na Cl iCa nCa TCa pH Mg TCO AG K Na Cl iCa nCa TCa pH Mg Li TCO AG
K Na Cl iCa nCa TCa pH Mg Li

 

Accessories
Model Description
YRA264 K Electrode
YRA265 K Electrode
YRA266 Cl Electrode
YRA267 Ca Electrode
YRA268 pH Electrode
YRA269 Li Electrode
YRA270 Mg Electrode
YRA271 Ref. Electrode
YRA272 Reagent Pack
Calibration A 430ml;
Calibration B 110ml;
( For Model H900
only)
YRA273 Reference Electrode
Internal
Solution – 10ml
YRA274 Electrode Internal

Solution – 3ml

YRA275 Activating Solution – 110ml
YRA276 QC Solution Level 2

(Water-based) – 110ml

YRA277 Cleaning Solution – 110ml
YRA278 Electrode Wash
Solution
(Protein Enzyme) -125mg
(25mg/bottle x5)
YRA278-1 Electrode Wash
Solution
(Diluent) – 5ml ( 1
bottle)

Additional information

Weight N/A
Dimensions 50 × 40 × 69 cm
model

YR06407, YR06408, YR06409, YR06410, YR06411, YR06412, YR06413, YR06414, YR06415, YR06416, YR06417

Bon de commande

No products in the list

Catégorie de produit

Dans cette section, vous pouvez sélectionner le secteur ou le produit qui vous intéresse.

FAQ

Vous avez besoin d'aide?

Si vous avez des questions avant de traiter la commande, consultez les questions les plus fréquemment posées.

Voulez-vous connaître le coût de la livraison aérienne de votre établissement?

Écrivez votre adresse dans les informations de paiement et voyez automatiquement les frais de port.

Nous sommes une institution – j’ai besoin de connaître le prix de plusieurs unités – je voudrais connaître le coût du fret maritime

Demandez un devis personnalisé dans la section CONTACT une fois que vous avez identifié le modèle.