Multi-Mode Microplate Reader YR06673

ManufacturerKalstein

Description

The Multi-Mode Microplate Reader YR06673 by Allsheng is a comprehensive solution designed to meet the most demanding requirements of modern laboratories. This equipment combines versatility and precision, offering multiple detection modes including Absorbance (Abs), Fluorescence (FL), and Luminescence (Lum) on a single platform.

Specifically aimed at medical, biological, and pharmaceutical research institutions, the YR06673 is the ideal tool for drug development and advanced life science studies. Its high detection performance ensures top-tier analysis in molecular biology, biochemistry, and cytology, positioning it as an indispensable asset for workflows requiring reproducible results and high sensitivity.

Design and Technology (or Functionality)

Stands out due to its modular and upgradeable architecture, allowing laboratories to scale their capabilities as needed. Key innovations include:

  • Xenon Flash Lamp: Provides a high-intensity full spectrum for stable detection across all wavelengths.
  • Multimode Optical System: Equipped with PD (Photodiode) detectors for absorbance and high-performance PMT (Photomultiplier Tube) for luminescence and fluorescence.
  • Wavelength Flexibility: Allows selection from 200 to 1000 nm, with a wavelength accuracy of 2 nm.
  • Modular Accessories: Offers a range of special detection accessories that are modular and upgradeable to optimize the detection experience even after initial purchase.
  • Rapid Reading: Capable of processing a 96-well plate in less than 15 seconds in fast mode, significantly optimizing laboratory productivity.

Frequently Asked Questions (FAQ)

  • Which reading modes are included in the standard Feyond-A300 model? The standard model includes Absorbance (200-1000 nm), Luminescence, and Fluorescence (top reading), covering the majority of current biological assays.
  • Is it possible to change the fluorescence filters? Yes, the unit comes with 3 standard filter groups (EX485/EM530, EX523/EM564, EX624/EM692), but these can be replaced with other wavelengths depending on your specific assay requirements.
  • What resolution does it offer for absorbance measurements? It provides a resolution of 0.0001 OD, allowing for the detection of extremely subtle changes in the optical density of samples.

Advantages and Disadvantages (Pros and Cons)

Advantages:

  • Total Versatility: Three detection modes integrated into one compact device.
  • High Sensitivity: Luminescence detection limit of 15 amol/well and 1 pM for fluorescence.
  • Processing Speed: Ideal for high-volume laboratories due to reduced reading times.
  • Modularity: Upgrade capability that protects your initial investment.

Disadvantages:

  • Learning Curve: As a multimode device, it requires training to fully master the analysis software features.
  • Weight: Due to high-precision optical components, it is a robust device that requires a fixed and stable location.

Field Use and Recommendations

The YR06673 performs exceptionally well in pharmaceutical research centers, academic hospitals, and biotechnology laboratories. It is highly recommended for cell viability assays, nucleic acid and protein quantification (DNA/RNA), and enzyme activity tests.

Pro Tip: To obtain the best results in fluorescence, it is recommended to use the condition optimization mode to adjust the detection limit to 1 pM. Additionally, perform periodic calibrations of the xenon lamp to ensure a wavelength repeatability of 0.2 nm.

Technical Specifications

Parameter characteristics
Model YR06673
Detection Modes Absorbance, Fluorescence (FL), Luminescence (Lum)
Light Source Xenon Flash Lamp
Detector Abs/FL-Lum PD (Absorbance) / PMT (Fluorescence & Luminescence)
Wavelength Range (Abs) 200 – 1000 nm (1 nm step)
Wavelength Accuracy 2 nm (Repeatability 0.2 nm)
Measurement Range (Abs) 0 – 4 OD (Resolution 0.0001 OD)
Reading Time (96-well) Fast mode < 15 seconds
Detection Limit (Lum) 15 amol / well
Dynamic Range (Lum/FL) 6 logs
Detection Limit (FL) 1 pM (optimization condition)
Standard FL Filters EX485/EM530, EX523/EM564, EX624/EM692
Wavelength Range (FL) EX: 200-1000 nm / EM: 270-850 nm
Accuracy (at 450 nm) ± (1.0 % + 0.003 Abs) @ (0.0-2.0 Abs]
Instrument Dimensions 44 cm x 48 cm x 32 cm
Instrument Weight 25 kg
Power Supply 100-240V AC, 50/60Hz

Additional information

Weight 25 kg
Dimensions 44 × 48 × 32 cm

Bon de commande

No products in the list

Catégories de produits

FAQ

Vous avez besoin d'aide?

Si vous avez des questions avant de traiter la commande, consultez les questions les plus fréquemment posées.

Voulez-vous connaître le coût de la livraison aérienne de votre établissement?

Écrivez votre adresse dans les informations de paiement et voyez automatiquement les frais de port.

Nous sommes une institution – j’ai besoin de connaître le prix de plusieurs unités – je voudrais connaître le coût du fret maritime

Demandez un devis personnalisé dans la section CONTACT une fois que vous avez identifié le modèle.