Automatic Nucleic Acid Extractor YR01869-2

FabricanteKalstein

Description

The Termocycler YR01869-2 is an innovative tool designed to optimize the nucleic acid extraction process. With rotary mixing technology (RMT), this device stands out for its ability to perform 16 x n different yields, allowing for simultaneous extraction of samples without interference. Its compact and flexible design makes it the ideal choice for laboratories with diverse assay needs. Additionally, it has won the prestigious Red Dot Design Award 2021 thanks to its user-friendly interface, which includes a 6.86-inch touch screen and remote control via a smartphone and tablet app.

Market Price

The price of the Termocycler YR01869-2 varies depending on the supplier and any additional services included. Generally, this type of advanced equipment is priced between $8350 and $8360 USD, making it a significant investment for laboratories and research centers. If you would like to receive a personalized quote and take advantage of exclusive discounts, you can generate an automatic quote through the Kalstein Plus platform. This service will allow you to get a tailored offer and access additional benefits such as specialized technical support.

Frequently Asked Questions

  • What types of samples can I process with the Termocycler YR01869-2? The YR01869-2 is capable of processing a wide variety of samples, especially those requiring precise nucleic acid extraction, such as DNA and RNA analysis.
  • Is this termocycler easy to use? Yes, the device features a 6.86-inch touch screen and a remote control system that facilitates its use from smartphones or tablets. The interface is intuitive and allows for quick and efficient experiments.
  • How do I maintain the equipment in good condition? Regular maintenance is important, including cleaning the device after each use and ensuring that the system is updated remotely to maintain optimal performance.

Advantages and Disadvantages

Advantages:

  • High Flexibility: Capable of managing multiple simultaneous projects with 16 x n different yields.
  • Automated Workflow: Automatic reagent identification and remote updates minimize manual intervention and improve efficiency.
  • Advanced Protection System: Equipped with UV lamps, internal negative pressure, and HEPA filtration to reduce contamination and ensure accurate results.
  • Compact and Portable Design: Its mobile design allows you to initiate experiments anywhere, making it suitable for various applications.

Disadvantages:

  • High Price: While it offers excellent value for money in terms of performance, its cost can be high for smaller laboratories with limited budgets.
  • Requires Specialized Maintenance: As an advanced device, it is essential to have trained personnel for maintenance and system updates.

Product Use in the Field

The Termocycler YR01869-2 is primarily used in genetic research laboratories, clinical diagnostic centers, and biotechnology applications. In environments like hospitals, forensic laboratories, or scientific research facilities, it is ideal for nucleic acid extractions, biological sample analysis, and PCR projects. Its ability to operate in any environment, thanks to its mobile power source and portable design, makes it indispensable in situations where flexibility and speed are essential for obtaining immediate results.

Recommendations

To optimize the performance of the Termocycler YR01869-2, it is recommended to follow the maintenance guidelines set by the manufacturer, such as regular cleaning of the device and updating reagent protocols. Additionally, since the device is designed to perform simultaneous tasks, it is important to maximize its capabilities by running multiple assays in parallel to increase laboratory productivity. Utilizing the UV disinfection system and HEPA filtration to prevent cross-contamination is essential for maintaining the accuracy of results.

Technical Specifications

Model YR01869-2
Throughput 16
Processing Volume 20-1700μL
Sample Processing Volume 200-500μL
Compatible Consumables Customized 96-deep-well plates, single 6-strip tubes
Inter-well Difference CV≤3%
Mixing Method Rotary mixing
Rotary Speed 100~3000rpm
Temperature Control Range Temperature control separately for lysis and elution.
Temperature range from 30°C to 120°C.
Temperature Control Accuracy Heating speed: 4.0±0.2°C/s.
Temperature accuracy: ±1.0°C.
Temperature uniformity:≤1.0°C.
Languages Chinese/English
Protocol Management Flexible to create, edit and delete protocols
Operation Mode Mode 1: Android systems in smartphones/tablets
Mode 2: 6.86 inch full-color LCD screen
Automatic Control Automatic opening and closing of the experiment cabin
Reagent Identification Automatic identification of reagent information and running the assays
Mixing Sleeve Monitoring Real-time monitoring of the mixing sleeves status in experiment
Magnetic Bead Residue ≤1%
Power Failure Protection Choose freely whether or not to continue the experiment when the power is on again after cutting off
Disinfection Ozone + UV disinfection
Auto Power-off Auto power-off after UV disinfection
Negative-Pressure Filtration Negative pressure HEPA filtration module
Connection Port Type USB port
Weight 7.4Kg (net)
Instrument Dimensions 210mm(L)*229mm(W)*242mm(H)
Power Supply AC220V, 50Hz

Additional information

Weight 11 kg
Dimensions 34 × 29 × 31 cm

Bon de commande

No products in the list

Catégorie de produit

Dans cette section, vous pouvez sélectionner le secteur ou le produit qui vous intéresse.

FAQ

Vous avez besoin d'aide?

Si vous avez des questions avant de traiter la commande, consultez les questions les plus fréquemment posées.

Voulez-vous connaître le coût de la livraison aérienne de votre établissement?

Écrivez votre adresse dans les informations de paiement et voyez automatiquement les frais de port.

Nous sommes une institution – j’ai besoin de connaître le prix de plusieurs unités – je voudrais connaître le coût du fret maritime

Demandez un devis personnalisé dans la section CONTACT une fois que vous avez identifié le modèle.