Kalstein

Multimode Microplate Reader YR07005

SKU:YR07005 · Par Kalstein

Catégorie:Microplate reader

Multimode Microplate Reader YR07005

The YR07005 multimode microplate reader represents a high-level analytical solution designed for medical research laboratories, biotechnology, and pharmaceutica

The YR07005 is a microplate reading system equipped with a continuous monochromator from 200 to 1000 nm and a photomultiplier tube (PMT) for ultra-sensitive readings. Its compatibility with the ultra-micro u-Nano plate allows quantification of samples from 2 to 4 µL without the need for prior dilutions. It incorporates interchangeable filter modules via QR codes, multidirectional shaking, and an optional automatic injector system with spill protection. With Ethernet, FTP, and USB connectivity, this instrument ensures smooth integration into biomedical data networks.

Advanced Design and Technology

  • 5 Mode Versatility: Adds Fluorescence Polarization (FP) to standard modes (ABS, FL, LUM, TRF), ideal for studying protein-protein and ligand-receptor interactions.

  • High Sensitivity Optics: Monochromator from 200 to 1000 nm with 1 nm steps for absorbance and independent filter-based optics with dichroic mirrors for high sensitivity assays.

  • Optimized Photomultiplier Tube (PMT): Maximizes detection of weak luminescent and fluorescent signals, reducing crosstalk between wells (crosstalk ≤0.005%).

  • Ultra-Micro u-Nano Plate: Allows simultaneous quantification of up to 16 or 96 nucleic acid and protein samples with volumes as low as 2 to 4 μL.

  • Integrable Lum-Check Microplate: Allows quick verification and standardization of the luminescence module to ensure continuous and reliable calibration.

Frequently Asked Questions (FAQ)

  • What is the Fluorescence Polarization (FP) mode used for? It is ideal for studying intermolecular interactions such as drug binding to receptors, DNA/protein interactions, and tyrosine kinase screening.

  • What plate formats are compatible? Supports standard plates of 6, 12, 24, 48, 96, and 384 wells, PCR plates, and the ultra-micro u-Nano plate.

  • Can custom protocols be saved? Yes, the ReaderIt-II software allows configuring and storing multiple analytical methods, managing data via FTP, USB, or Ethernet export.

Advantages and Disadvantages

Key Advantages:

  • Maximum Analytical Coverage: The 5 detection modes in a single device eliminate the need for multiple instruments in the laboratory.

  • Extreme Detection: Achieves sensitivity limits of up to 1 pM in fluorescence and ≤15 amol/well in luminescence.

  • Long-Lasting Xenon Lamp: Capable of performing up to $10^9$ flashes with a continuous spectral scanning time of less than 15 seconds.

Disadvantages / Considerations:

  • Space and Weight Requirement: Being a complete analytical device of 33 kg, it requires a stable and level laboratory table.

  • Technical Training: The advanced use of the FP mode and the configuration of dual injectors requires training from laboratory personnel.

Product Use in the Field and Recommendations

  • Ideal Applications: Pharmaceutical R&D centers, molecular biology laboratories, oncology research, immunoassays, and drug discovery.

  • Recommended Maintenance: Use ABS and Lum-Check optical performance validation plates for periodic operational qualifications.

  • Operation Recommendation: Scan the QR code of the filter modules for automatic loading of measurement parameters and avoid manual configuration errors.

ModelYR07005
ABS
Plate6 well plate, 12 well plate, 24 well plate, 48 well plate, 96 well plate, 384 well plate, 96/384 PCR plate, ultra-micro uNano 16/96 plate
Reading time (spectrum)200~1000 nm <15 s (1 nm step)
Light sourceXenon lamp
Wavelength accuracy2 nm
Wavelength repeatability (SD)0.2 nm
Half width (FWHM)<2.5 nm
DetectorPD×2
Wavelength range200~1000 nm, 1 nm step
Measurement range0-4 DE
Resolution0.0001 DE
Accuracy at 450 nmPrecision mode: ±(1.0%+0.003OD) @(0.0-2.0OD]; ±2%>@(2.0-3.0OD]
Repeatability at 450 nmCV<1.0% or SD<0.003 fast (0.0-3.0 OD]; CV<0.5% or SD<0.003 precise (0.0-3.0 OD]
Scattered light0.1 % at 220 nm
Linear at 450 nmR²≥0.999 @ [0.0 - 3.0 OD]
Reading time96 well plate: fast <15 s (A1 to H1)
Fluorescence
Reading modeHighlighted readings
Excitation light sourceXenon lamp
DetectorPMT
Wavelength rangeEX: 200~1000 nm; EM: 270~850 nm
EX / EM filterEX485 / EM530, EX523 / EM564, EX624 / EM692 (other wavelengths can be substituted)
Linear dynamic range≥6 logs
Detection limit1 pM (optimization condition)
LUMINESCENCE
DetectorPMT
Detection limit≤15 amol/well on 96 well white plate with ATP flash
Linear dynamic range≥6 logs
Crosstalk≤0.005%
Wavelength range200-850 nm
FilterLUMINESCENCE
TRF
EX / EM filterEX365 / EM612
Detection limit0.02 pM (optimization condition)
FP
EX / EM filterEX485 / EM530
Detection limitsd ≤5 mP @1 nm sodium fluorescein
Software
Analysis softwareReaderIt-II Software
Basic parameter
Reading typeEnd point, kinetics, spectral scanning, and well scanning
Plate6 well plate, 12 well plate, 24 well plate, 48 well plate, 96 well plate, 384 well plate, 96/384 PCR plate, ultra-micro u-Nano 16/96 plate
AccessoriesUltra-micro u-Nano 16/96 plate, auto-injector
Stirring modeLinear, circular, double circular (force and speed adjustable)
Incubation temperatureTA. +4 °C~45 °C
Temperature accuracy±0.5 °C at 37 °C
Software interfaceChinese / English
Screen size10 inches
Operation methodCapacitive touch screen, mouse
Data capacity10 GB
CompatibilityCompatible with PC software, Windows 10 and later versions, 64 bits.
Network transmissionTest data report can be uploaded to the PC server via FTP.
Instrument port2 USB A ports, 1 USB B port, 1 Ethernet port, RS232 bus interface (connected to injector)
Power supplyAC 100-240 V, 50-60 Hz
Equipment dimensions42×55×38.6 cm
Packing dimensions80 x 78 x 80 cm
Weight33 kg
Accessory parameter
u-Nano
Sample numberu-Nano 16: 1~16, u-Nano 96: 1~96
Sample detection volume2-4 μL
Automatic injector
Support plate6-384 well plate
Quantity1/2
Dispensing volume5-1000 μL, increment of 1 μL
Liquid injection speed125-500 μL/s
Accuracy±1 μL at 5-50 μL; ±2% at 51-1000 μL
Residual liquid collection25 ml

Spécifications techniques

FabricantKalstein

Vidéo Multimode Microplate Reader YR07005

Questions fréquentes

Comment connaître les prix de Multimode Microplate Reader YR07005 ?

Pour connaître le prix de Multimode Microplate Reader YR07005, envoyez-nous un e-mail via le formulaire de contact AQUI.

Quels sont les délais de livraison de Multimode Microplate Reader YR07005 ?

Le délai dépend du stock et du fret (aérien ou maritime). En stock : aérien 15-30 jours, maritime 45-60 jours. Hors stock : aérien 30-60 jours, maritime 60-90 jours.

Comment effectuer un achat de Multimode Microplate Reader YR07005 ?

Vous pouvez acheter par e-mail ([email protected]), téléphone (+33 (0) 1 70 39 26 50) ou via le site officiel Kalstein de votre pays.

Comment fonctionne la garantie de Multimode Microplate Reader YR07005 ?

Tous les équipements Kalstein sont garantis 1 an contre les défauts de fabrication. La garantie ne couvre pas les dommages dus à une mauvaise installation ou utilisation. Consultez nos «conditions générales» AQUI.

Puis-je demander un devis en ligne de Multimode Microplate Reader YR07005 ?

Oui, vous pouvez demander un devis directement sur notre site officiel. Cliquez AQUI.