The Moniteur Doppler fœtal YR02180 is a versatile and highly advanced medical device designed to monitor vital signs during surgical operations and intensive care unit stays. Featuring a large 17-inch LCD screen, this fetal Doppler monitor is semi-modular, offering six standard parameters: ECG, SpO2, TEMP, NIBP, RESP, and PR/HR. With optional add-ons such as a touchscreen, Masimo/Nellcor SpO2, dual-IBP, and more, this device is tailored to meet the diverse needs of healthcare providers. Its robust design coupled with precision technologies ensures accurate readings, making it an indispensable tool in medical settings.
Market Price
The market price for fetal Doppler monitors like the YR02180 varies based on features and optional additions. The price range typically falls between $3500 and $4250 USD, aligning with the technological advancements and capabilities the device offers.
Frequently Asked Questions
What are the standard parameters of this model?
This monitor comes with standard ECG, SpO2, TEMP, NIBP, RESP, and PR/HR parameters.
Is the screen touch-sensitive?
The model can be upgraded to feature an optional touchscreen.
Advantages and Disadvantages
Advantages: The monitor boasts an impressive array of features with high accuracy rates, offering healthcare professionals the reliability they need. The large display enhances usability, and the modular design allows for customization.
Disadvantages: The initial cost can be high, and some advanced optional features may require additional investment.
Product Usage in the Field
The Moniteur Doppler fœtal YR02180 is primarily used in operating theaters and intensive care units. Its ability to provide accurate real-time monitoring of vital signs makes it crucial during critical medical procedures and patient recovery phases.
Recommendations
For optimal use, calibrate the device regularly. Ensure it is installed by qualified personnel to guarantee it functions as intended. Regular training on device operation and maintenance is recommended to maximize its lifespan and performance.
Features
- 17-inch LCD display
- Semi-modular design
- Standard parameters: ECG, SPO2, TEMP, NIBP, RESP, PR/HR
- Optional features include touch screen, Masimo/Nellcor SpO2, Dual-IBP and more
Technical Specifications
Model | YR02180 | |
ECG | Lead mode | 5 Leads (RA, LA, LL, RL, V) |
Connection method | I, II, III, AVR, AVL, AVF, V | |
Lead Mode | 3 Leads (RA, LA, LL) | |
Connection method | I, II, III | |
Gain | x250, x500, x1000, x2000 | |
Accuracy | ±5% | |
Resolution | 1 bpm | |
Sensitivity | 200 (uVp-p) | |
Differential input impedance | ≥5MΩ | |
ST segment Monitoring Range | ||
Measure Range | -1.0~+1.0 mV | |
Measure Accuracy | -0.8 mV~+0.8 mV | |
Heart Rate | Measuring range | 40~240 bpm |
Accuracy | ±3 bpm | |
Resolution | 1 bpm | |
Sensitivity | 200 UVp-p | |
Respiration | Method | Impedance between R-F (RA-LL) |
Measuring Impedance Range | 0.3~3.0 MΩ | |
Bandwidth | 0.1~2.5 Hz | |
Resp. Rate | Adult: 7~120 BrPM | |
Neo/Ped | 7~150 BrPM | |
Resolution | 1 BrPM | |
Accuracy | ±2 BrPM | |
NIBP | Method | Oscillometric |
Measuring Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240(Min) | |
Measuring Period in STAT Mode | 5 Min | |
Pulse Rate Range | 40~240 bpm / 40~150 bpm | |
Alarm Type | SYS, DIA, MEAN | |
Resolution | ||
Pressure | 1 mmHg | |
SPO2 | Display | Number of SPO2, waveform of capacity, Pulse |
Measuring range | 0~100% | |
Resolution | 1% | |
Accuracy | 70~99% (±2%) | |
Pulse rate range | 0~300 bpm | |
TEMP | Channel | 2 |
Measuring and Alarm Range | 0~50ºC | |
Resolution | 0.1ºC | |
Accuracy | 0.1ºC | |
Actualization interval | about 1 Second | |
Average Time Constant | <10 Second |