Kalstein

Hotte de laboratoire, résistance aux acides et aux alcalis, équipement de laboratoire hospitalier YR05820//YR05822

SKU:YR05820 · Par Kalstein

Catégorie:Hottes aspirantes

Hotte de laboratoire, résistance aux acides et aux alcalis, équipement de laboratoire hospitalier YR05820//YR05822

Hotte de laboratoire, résistance aux acides et aux alcalis, équipement de laboratoire hospitalier YR05820//YR05822 — équipement de laboratoire Kalstein avec spécifications techniques, caractéristiques avancées et solutions professionnelles certifiées pour usage scientifique.

The YR05820 // YR05822 laboratory fume hood is specifically designed to offer maximum safety and efficiency while handling aggressive chemicals. Constructed with a main body of epoxy resin powder-coated stainless steel, this hood is resistant to strong acids and alkalis, providing a durable and reliable solution for laboratories and hospitals. It features a 5mm thick tempered glass front window that is manually adjustable, protecting the operator from exposure to toxic fumes. Additionally, its 12.7mm phenolic resin work surface provides chemical resistance, ensuring long-term durability. The ventilation system, equipped with an adjustable axial flow fan and a noise level below 60 dB, ensures a controlled and contaminant-free working environment.

Market Price

The market price for the YR05820 // YR05822 laboratory hood ranges from $2,600 to $3,500, depending on the model and specifications selected. This price reflects the quality of the materials, such as stainless steel and phenolic resin, as well as the advanced technology included to guarantee safety in critical environments. This hood is an excellent investment for laboratories and hospitals aiming to meet high standards of safety and operational efficiency.

Frequently Asked Questions

  • Is the YR05820 // YR05822 hood easy to use?
    Yes, the hood is designed for ease of use, featuring a manual front window and a simple control panel that allows adjustment of fan speed and window height.
  • What type of protection does it offer?
    This hood protects the operator from exposure to toxic chemical fumes and ensures a safe working environment through its adjustable ventilation system and corrosion-resistant materials.
  • What is the noise level during operation?
    The noise level is below 60 dB, making it a quiet and efficient option for laboratories.

Advantages and Disadvantages

The main advantages of the YR05820 // YR05822 hood include its robust stainless steel construction and chemical-resistant work surface. Additionally, its adjustable ventilation and low noise level offer a comfortable and safe working environment. However, its price may be considered high compared to other hoods on the market, which may pose a challenge for laboratories with tighter budgets.

Field Usage

This hood is ideal for use in chemical laboratories and hospitals handling hazardous substances. Thanks to its resistance to acids and alkalis, it can be used for intensive and prolonged work, where exposure to corrosive substances is common. Its ventilation system effectively eliminates fumes, thereby protecting the operator and the working environment.

Recommendations

To maintain the YR05820 // YR05822 hood in good condition, regular maintenance is recommended. This includes cleaning the ventilation ducts and checking the fan and window controls. Be sure to use it within the recommended airflow speed parameters to prolong its durability and efficiency.

Features

- Epoxy resin powder-coated stainless steel construction

- 5mm thick tempered glass front window, manually adjustable

- 12.7mm phenolic resin work surface

- Adjustable axial flow fan, noise level ≤60 dB

- LED lamp, standard accessories with waterproof sockets

- Optional external centrifugal blower, resistant to strong acids and alkalis

Technical Specifications

ModelYR05820YR05821YR05822
External Size (L x D x H) (mm)1200*800*15001500*800*15001800*800*1500
Internal Size (L x D x H) (mm)950*700*11501250*700*11501550*700*1150
Worktop Height800mm
Max Window Opening750mm
Air Speed/Air Volume Exhaust0.4-0.6m/s, 800-1000m³/h
Noise≤60dB
LED Lamp10W*1
FanBuilt-in axial flow fan; adjustable speed.
Front WindowManual, 5mm tempered glass, adjustable height.
Power SourceAC220V±10%, 50/60Hz ;
Consumption100W
MaterialMain Body1.2mm thick stainless steel with epoxy resin powder coating.
Interior Side5mm thick compact, resistant to strong acids and alkalis.
Work TableChemical resistant phenolic resin, 12.7mm thick.
Standard AccessoryLED lamp, built-in axial flow fan with adjustable speed.
Waterproof socket * 3
3m PP duct, diameter: 250mm
Optional AccessoryExternal centrifugal blower (300W), resistant to strong acids and alkalis.
Gross Weight235265300

Spécifications techniques

FabricantKalstein

Vidéo Hotte de laboratoire, résistance aux acides et aux alcalis, équipement de laboratoire hospitalier YR05820//YR05822

Questions fréquentes

Comment connaître les prix de Hotte de laboratoire, résistance aux acides et aux alcalis, équipement de laboratoire hospitalier YR05820//YR05822 ?

Pour connaître le prix de Hotte de laboratoire, résistance aux acides et aux alcalis, équipement de laboratoire hospitalier YR05820//YR05822, envoyez-nous un e-mail via le formulaire de contact AQUI.

Quels sont les délais de livraison de Hotte de laboratoire, résistance aux acides et aux alcalis, équipement de laboratoire hospitalier YR05820//YR05822 ?

Le délai dépend du stock et du fret (aérien ou maritime). En stock : aérien 15-30 jours, maritime 45-60 jours. Hors stock : aérien 30-60 jours, maritime 60-90 jours.

Comment effectuer un achat de Hotte de laboratoire, résistance aux acides et aux alcalis, équipement de laboratoire hospitalier YR05820//YR05822 ?

Vous pouvez acheter par e-mail ([email protected]), téléphone (+33 (0) 1 70 39 26 50) ou via le site officiel Kalstein de votre pays.

Comment fonctionne la garantie de Hotte de laboratoire, résistance aux acides et aux alcalis, équipement de laboratoire hospitalier YR05820//YR05822 ?

Tous les équipements Kalstein sont garantis 1 an contre les défauts de fabrication. La garantie ne couvre pas les dommages dus à une mauvaise installation ou utilisation. Consultez nos «conditions générales» AQUI.

Puis-je demander un devis en ligne de Hotte de laboratoire, résistance aux acides et aux alcalis, équipement de laboratoire hospitalier YR05820//YR05822 ?

Oui, vous pouvez demander un devis directement sur notre site officiel. Cliquez AQUI.