The Full-auto Hematology Analyzer YR05120 is an advanced solution designed for laboratories seeking to enhance precision and efficiency in blood sample analysis. This state-of-the-art device features an individual polling channel, providing 23 parameters, including 3 histograms, for comprehensive and reliable results. Its large 8.0″ TFT color LCD monitor with mouse operation facilitates easy interaction and data visualization, making it user-friendly for laboratory personnel. With three counting modes – whole blood, previously diluted blood, and peripheral blood – the YR05120 offers versatility in handling various sample types.

Equipped with a robust memory capacity and multi-format output for test results, the YR05120 ensures efficient data management and reporting. The device includes backwashing, soaking, and high voltage burning functions to remove clogs in the reading chamber, maintaining optimal performance. The innovative 3-door opening design simplifies maintenance, allowing for quick and easy access to the internal components. This hematology analyzer can process up to 30 samples per hour, making it ideal for laboratories with moderate sample volumes.

Market Price

The price of the Full-auto Hematology Analyzer YR05120 ranges between $6000 and $8000 USD, depending on additional features and the supplier. This price range reflects the advanced technology and high precision of the equipment. To obtain a personalized quote tailored to your laboratory’s specific needs, we invite you to visit the Kalstein Plus platform. There, you can quickly and easily generate an automatic quote, optimizing your investment in high-quality equipment.

Frequently Asked Questions

  • How many samples can the YR05120 process per hour?
    The YR05120 can process up to 30 samples per hour.
  • What types of samples can this device analyze?
    The YR05120 is compatible with whole blood, previously diluted blood, and peripheral blood samples.
  • What technologies does the YR05120 use to prevent clogging?
    The YR05120 includes backwashing, soaking, and high voltage burning to remove clogs in the reading chamber.

Advantages and Disadvantages

Advantages:

  • High Precision: Thanks to its advanced analysis technologies.
  • Versatility: Three counting modes for different sample types.
  • Ease of Maintenance: 3-door opening design for easy access and maintenance.

Disadvantages:

  • Initial Cost: The investment can be significant for some laboratories.
  • Sample Throughput: Processes up to 30 samples per hour, which may be lower than needed for high-volume labs.

Field Use

The YR05120 is ideal for clinical and research laboratories that handle a moderate volume of samples daily. Its ability to process up to 30 samples per hour and its compatibility with various sample types make it versatile and efficient. Laboratories can benefit from the precision and reliability of the YR05120, ensuring consistent and accurate results in hematological analyses.

Recommendations

To maximize the performance of the Full-auto Hematology Analyzer YR05120, it is essential to follow the manufacturer’s recommendations for maintenance and calibration. Perform periodic inspections and keep the system clean to prevent build-ups that could affect accuracy. Additionally, adequately train personnel in the use of the instrument to ensure efficient operation and prolong the equipment’s lifespan.

To enhance your laboratory capabilities and obtain a reliable and precise hematology analysis device, consider the Full-auto Hematology Analyzer YR05120. Visit the Kalstein Plus platform to request a personalized quote or generate an automatic quote today. Don’t miss the opportunity to optimize your laboratory with this advanced technology.

Technical Specifications

Model: YR05120
Sample Volume: Prediluted:20uL;Whole Blood:9.8uL
Throughput: Up to 30 samples per hour
Display: 8.0″TFT color LCD with mouse operation
Alarms: Error messages
Input/Output: RS-232,USB,LAN,keyboard and mouse interface
Printout: “Thermal recorder,55mm width paper, various
Operating Environment: Temperature:15℃-35℃;Humidity:≤80%
Power Requirement: a.c.100-240V,50-60±1Hz
Dimension: L×W×H(mm): 468×325×395
Weight: 16.5Kg

Additional information

Weight 22 kg
Dimensions 52 × 48 × 61 cm

Bon de commande

No products in the list

Catégorie de produit

Dans cette section, vous pouvez sélectionner le secteur ou le produit qui vous intéresse.

FAQ

Vous avez besoin d'aide?

Si vous avez des questions avant de traiter la commande, consultez les questions les plus fréquemment posées.

Voulez-vous connaître le coût de la livraison aérienne de votre établissement?

Écrivez votre adresse dans les informations de paiement et voyez automatiquement les frais de port.

Nous sommes une institution – j’ai besoin de connaître le prix de plusieurs unités – je voudrais connaître le coût du fret maritime

Demandez un devis personnalisé dans la section CONTACT une fois que vous avez identifié le modèle.