The Armoire à flux laminaire (Double personne) YR05267-1 is designed to provide a safe and controlled working environment, making it ideal for applications in biotechnology, pharmaceuticals, life sciences, and precision electronics. This advanced hood, combined with CLEANFLOW™ technology, ensures a uniform and stable airflow, guaranteeing the protection of both the operator and the product during experiments. Equipped with an integrated LCD screen, the system allows real-time monitoring of lighting, sterilization, and airflow, ensuring an optimal working environment. Additionally, the low-consumption centrifugal fan and high-efficiency HEPA filter capture 99.99% of particles, creating a completely contaminant-free environment.

Market Price

The price of the Armoire à flux laminaire YR05267-1 ranges from $3600 to $4400, depending on additional specifications and the supplier. This price range reflects the advanced airflow technology, high-quality materials, and durability of the unit, making it a solid investment for laboratories demanding the highest standards of air purification and protection in their work processes.

Frequently Asked Questions

  • What type of airflow does this hood use? The hood offers horizontal and vertical airflow options, designed to meet the specific needs of the user according to their environment’s requirements.
  • Is the airflow speed adjustable? Yes, the airflow speed is fully adjustable between 0.3 to 0.6 m/s, allowing precise control tailored to working conditions.
  • What is the operating noise level? The noise level is below 62 dB, ensuring a quiet and comfortable working environment.

Advantages and Disadvantages

The main advantages of the YR05267-1 laminar flow hood include its quiet operation, adjustable airflow speed, and highly efficient HEPA filtration system. Additionally, its ergonomic and safe design protects the operator from ultraviolet radiation with its locking function. However, the unit’s size and weight (235 kg during shipping) may require additional planning for transport and installation.

Field Usage

This equipment is ideal for environments requiring high sterility levels, such as biotechnology, pharmaceutical, and life sciences research laboratories. With its capacity to accommodate two people, it is perfect for collaborative projects where air purification and protection are essential. Its controlled airflow prevents particles from contaminating the workspace, making it indispensable for handling sensitive samples and precision electronic products.

Recommendations

To maximize the performance and longevity of the YR05267-1 laminar flow hood, regular maintenance of the HEPA filter is recommended, as well as periodic checks of airflow speed and sterilization system. It is also crucial to ensure that the environment is free of vibrations and dust to guarantee optimal operation. If you want to improve the safety and efficiency of your laboratory, request a quote today via Kalstein Plus and discover how the YR05267-1 laminar flow hood can optimize your workspace by providing a constantly clean and controlled environment.

Features

  • Model: YR05267-1
  • International Standard ISO 14644.1, CLASS 5
  • Adjustable Airflow Speed: 0.3 ~ 0.6 m/s
  • Noise: ≤62 dB
  • Vibration Half-Peak: ≤3μm (X, Y, Z directions)
  • HEPA Filter Efficiency: 99.99%
  • Lighting: ≥300 LX
  • Working Environment: Ambient temperature 10 ~ 30 ℃, relative humidity below 70%
  • Overall Size (mm)(H×W×D): 1585×1460×735
  • Inner Size (mm)(H×W×D): 500×1300×550
  • Voltage: AC220V/50Hz
  • Power: 400 W
  • Net Weight: 210 kg
  • Shipping Weight: 235 kg
  • Package Size (mm) (H×W×D): 1030×1650×855

Technical Specifications

Model YR05267-1
Cleanliness Rating International Standard ISO 14644.1, CLASS 5 (US Federal 209E, Level 100)
Wind Speed 0.3 ~ 0.6 m/s (adjustable)
Noise (dB) ≤62
Vibration Half-Peak ≤3μm (direction X, Y, Z)
High-Efficiency Filter Efficiency 99.99%
Lighting (LX) ≥300
Working Environment Ambient temperature 10 ~ 30 ℃, relative humidity
below 70%, no obvious vibrations and dust around
Overall Size (mm)(H×W×D) 1585×1460×735
Inner Size (mm)(H×W×D) 500×1300×550
Voltage(V) AC220V/50Hz
Power (W) 400
Net Weight (kg) 210
Shipping Weight (KG) 235
Package Size (mm) (H×W×D) 1030×1650×855

Informations complémentaires

Poids 235 kg
Dimensions 156 × 83.5 × 124 cm

Bon de commande

Pas de produits sur le bon de commande

Catégorie de produit

Dans cette section, vous pouvez sélectionner le secteur ou le produit qui vous intéresse.

FAQ

Vous avez besoin d'aide?

Si vous avez des questions avant de traiter la commande, consultez les questions les plus fréquemment posées.

Voulez-vous connaître le coût de la livraison aérienne de votre établissement?

Écrivez votre adresse dans les informations de paiement et voyez automatiquement les frais de port.

Nous sommes une institution – j’ai besoin de connaître le prix de plusieurs unités – je voudrais connaître le coût du fret maritime

Demandez un devis personnalisé dans la section CONTACT une fois que vous avez identifié le modèle.