Biosafety Cabinet Class Ii A2 Yr0090-a

The Biosafety Cabinet Class II A2 YR0090-A is designed for laboratories that require a high level of protection while working with hazardous materials. This cabinet ensures both user safety and the integrity of samples during research and testing.
With advanced engineering and features, the YR0090-A provides a controlled environment that minimizes exposure to airborne contaminants, making it a crucial investment for any laboratory focused on safety and compliance.
What you should know before selecting a biosafety cabinet class ii a2 yr0090-a and making an investment
Key factors to consider

When selecting a biosafety cabinet, consider factors such as airflow patterns, filter efficiency, and the type of materials you'll be handling. Understanding the specific needs of your laboratory will aid in determining the best fit for your safety requirements.
It is essential to assess the cabinet's certification and compliance with international standards to ensure optimal protection for both users and samples.
Market price range

The market price for a Class II A2 biosafety cabinet can vary significantly based on features, brand reputation, and specifications. Typically, you can expect to invest in a range from several thousand to tens of thousands of dollars, depending on the complexity and additional functionalities.
It's advisable to compare prices and features across different models to ensure you're getting the best value for your investment.
Value for money

Investing in a high-quality biosafety cabinet is crucial for long-term safety and efficiency in laboratory operations. A more expensive cabinet often offers better durability, advanced filtration systems, and lower maintenance costs over time.
Evaluate the return on investment by considering the potential costs associated with safety breaches, sample contamination, or regulatory fines that may arise from using inferior equipment.
Expected lifespan based on use and maintenance

The expected lifespan of a biosafety cabinet largely depends on its usage and maintenance. With proper care, most cabinets can last between 10 to 15 years, making regular maintenance and filter replacement essential for optimal performance.
Establishing a maintenance schedule and using the cabinet according to the manufacturer's guidelines can significantly extend its operational life.
BIOSAFETY CABINET CLASS II A2 YR0090-A KALSTEIN
Discover biosafety cabinet class ii a2 yr0090-a for your laboratory
The Biosafety Cabinet Class II A2 YR0090-A from Kalstein represents a top-tier solution for laboratories requiring stringent safety measures. This cabinet combines advanced technology with user-friendly features to ensure both safety and efficiency in laboratory practices.

Biological Safety Cabinet Class II A2 YR0090B (SS) // YR0090E (SS)
The Class II A2 Biological Safety Cabinet YR0090B (SS) // YR0090E (SS) from Kalstein provides unmatched protection in laboratories handling low to mod
View product
Biosafety cabin YR06543 // YR06547
The biological safety cabinet, models YR06543 // YR06547, is a state-of-the-art solution designed to protect personnel, products, and the environment
View product
Biological Safety Cabinet YR05270-1 // YR05271-1
The Biological Safety Cabinet YR05270-1 // YR05271-1 is an essential tool for any laboratory handling materials contaminated with pathogens. Designed
View product
Biological Safety Cabinet YR05270 - YR05271
The Biological Safety Cabinet YR05270 – YR05271 is an advanced solution designed to provide maximum protection in laboratory environments that require
View productOur best-selling biosafety cabinet class ii a2 yr0090-a

Biosafety cabin YR06543 // YR06547
Frequently Asked Questions
What is the difference between ULPA and HEPA filters? The G series uses ultra-high-efficiency ULPA filters (99.999% efficiency), while the D series uses high-efficiency HEPA filters (99.995% efficiency). Both are excellent, but ULPA offers a slightly higher level of purity. What is the accuracy of the downward airflow control? The accuracy of the downward airflow control is 0.015 m/s, which ensures uniformity and stability of the flow to maintain sterility in the work area. What sizes are available? What level of cleanliness does the cabinet guarantee? The cabinet guarantees level 5 of the international standard ISO14644.1 (class 100 US Federal 209E), a strict requirement for sensitive environments.Advantages and disadvantages
Advantages: Double filtration: uses external HEPA filters and downward ULPA/HEPA filters, ensuring up to 99.999% efficiency. Superior safety (negative pressure): the negative pressure design prevents leaks, thus protecting the operator and the environment. Optimized design: reasonable air duct and optimized negative pressure box for flow uniformity. High-performance German motor: uses a low-power, high-air-volume EBM motor. Durable construction: corrosion-resistant cold-rolled steel and epoxy resin surface treatment. Disadvantages: Environmental requirements: the working environment must be maintained between 10 and 30°C with relative humidity below 70%. Shipping weight: the shipping weight is considerable, ranging from 138 kg to 198 kg (depending on size), which can complicate transport and installation. Flow limitations: although it is a recirculation system (70% internal), the 30% external discharge requires an exhaust ventilation system.Product use in the field
The Class II Type A2 biological safety cabinet is indispensable for handling low to moderate risk biological agents, such as viruses, bacteria, and cell cultures, which require biosafety. It is the standard choice in microbiology laboratories, hospitals, and biotechnology and pharmaceutical research centers, where protection of the product, personnel, and environment is essential. Its vibration control capability (half-wave: 3 μm) and stable airflow are essential for delicate experiments.Recommendations
To ensure longevity and maximum safety: Perform regular maintenance on the filters and check the calibration of the imported sensor. Check that the working environment meets the temperature (10-30 °C) and humidity (below 70%) requirements. Periodically check the inlet flow velocity (average of 0.53 m/s to 0.56 m/s) and downward airflow velocity (average of 0.35 m/s) to ensure the effectiveness of negative pressure protection. Use heavy-duty casters (heavy-duty mobile wheels) for initial positioning and ensure that it is stable before use.Technical specifications
| Description | YR06543 | YR06544 | YR06545 | YR06546 | YR06547 |
| Package Size (mm) | 110*100*140 | 130*100*140 | 160*100*140 | 190*100*140 | 210*100*140 |
| External Size (mm) | 900*760*2250 | 1100*760*2250 | 1300*760*2250 | 1500*760*2250 | 1800*760*2250 |
| Internal Size (mm) | 740*600*600 | 940*600*600 | 1140*600*600 | 1340*600*600 | 1640*600*600 |
| Lamp | LED fluorescent test lamp with three conditions | ||||
| Work Surface | Brushed stainless steel SUS304# | ||||
| Cabinet | Cold-rolled steel plate 1.0 mm thick with epoxy resin coating on the surface | ||||
| Fan | Built-in fan 220V, 138W, 250mm diameter | ||||
| Filter | Technical parameters of high-efficiency partitionless filter | ||||
| Window | 5mm tempered glass | ||||
| Lighting and UV | UV disinfection lamp * 1, LED lamp 10W * 2 | ||||
| Electrical Outlets | Waterproof socket 10A * 2, installed on the rear wall | ||||
| Voltage | 220V / 50HZ | ||||
| Filtration and Ventilation | Equipped with HEPA filter * 2, integrated 300W centrifugal fan | ||||
| Airflow | 30% air exhaust, 70% air recirculation | ||||
| Control Panel | LCD digital control panel | ||||
| Packaging | Complete packaging with rigid carton and wooden box | ||||
| Mobility | Heavy duty castors | ||||
Detailed analysis of biosafety cabinet class ii a2 yr0090-a for an effective and safe choice
Kalstein Class II Biosafety Cabinet: Enhancing Safety and Efficiency in the Laboratory
The laboratory environment requires the highest degree of accuracy and safety possible. When dealing with various biological specimens, it is essential to have equipment that provides safety for the user, the environment and the sample. Among the different tools in a laboratory, the Class II Biosafety Cabinet (CBC II) is essential for working with biological agents.

Biosafety Cabinets with Advanced Protection for Personnel and Samples
Safety in the laboratory environment is a fundamental aspect to ensure the protection of both personnel and the samples being handled. Biosafety cabinets play a crucial role in this regard, offering a controlled environment that minimizes the risk of cross-contamination and exposure to biological agents. In this article, we will explore in detail the features and benefits of biosafety cabinets, focusing on the solutions offered by the KALSTEIN brand and comparing them with other options available on the market.

Biosafety Cabinets: Efficient Protection in Controlled Environments
In research laboratories and medical centers where hazardous or contaminant biological substances are handled, the protection of the environment and personnel is crucial. Biosafety cabinets are specifically designed for this purpose: to protect the operator, the product, and the environment by ensuring a controlled and safe work environment. These cabinets are essential in a wide range of applica

Exploring Kalstein’s Laminar Flow Hoods, Clean Benches, and Biosecurity Cabinets: Safety and Efficiency in the Laboratory
Discover the excellence of Kalstein’s laminar flow hoods, clean benches, and biosecurity cabinets, ensuring safety and efficiency in laboratory settings.
biosafety cabinet class ii a2 yr0090-a offer catalog

Biological Safety Cabinet YR05708 // YR05710
Ver producto
Biological Safety Cabinet 100% Exhaust Class II A2 Biosafety Cabinet YR05704 // YR05707
Ver producto
Biological Safety Cabinet Class II A2 YR0090B (SS) // YR0090E (SS)
Ver producto
Biosafety cabin YR06543 // YR06547
Ver producto
Biological Safety Cabinet YR05270-1 // YR05271-1
Ver producto
Biological Safety Cabinet YR05270 - YR05271
Ver producto
Biological Safety Cabinet YR05708 // YR05710
Ver producto
Biological Safety Cabinet 100% Exhaust Class II A2 Biosafety Cabinet YR05704 // YR05707
Ver productoGuides about biosafety cabinet class ii a2 yr0090-a
Complete guides to choose biosafety cabinet class ii a2 yr0090-a
Usefulness of biosafety cabinets for the preparation of sterile topical and urological solutions
Sterile topical solutions are any that are performed under strict aseptic parameters and are usually marketed as rinses, aerosols, or drops. They usually have low viscosity and often contain water or alcohol as a base. Sterile compounding i
Leer másThe use of biosafety cabinets for HIV sample studies
HIV (Human Immunodeficiency Virus) is a virus that attacks the body's immune system, which, if left untreated, can cause AIDS (Acquired Immune Deficiency Syndrome). HIV infection in humans originated from a type of chimpanzee in central Afr
Leer másAvailable protection levels of the full steel biological safety cabinet for laboratory use
The full steel biological safety cabinet for the laboratory is a device specifically designed to provide protection for users while working with high-risk biological material. This cabinet is designed to provide various levels of protection
Leer más
Optimal Protection in Laboratories with Biological Safety Cabinets and Fume Hoods
Protection in laboratories is crucial not only to ensure the integrity of samples but also to safeguard workers from hazardous biological or chemical agents. Biological Safety Cabinets and Fume Hoods have become essential tools to prevent c
Leer másQuestions fréquentes sur Biosafety Cabinet Class Ii A2 Yr0090-a
Comment connaître les prix de Biosafety Cabinet Class Ii A2 Yr0090-a ?
Pour connaître le prix de Biosafety Cabinet Class Ii A2 Yr0090-a, envoyez-nous un e-mail via le formulaire de contact AQUI.
Quels sont les délais de livraison de Biosafety Cabinet Class Ii A2 Yr0090-a ?
Le délai dépend du stock et du fret (aérien ou maritime). En stock : aérien 15-30 jours, maritime 45-60 jours. Hors stock : aérien 30-60 jours, maritime 60-90 jours.
Comment effectuer un achat de Biosafety Cabinet Class Ii A2 Yr0090-a ?
Vous pouvez acheter par e-mail ([email protected]), téléphone (+33 (0) 1 70 39 26 50) ou via le site officiel Kalstein de votre pays.
Comment fonctionne la garantie de Biosafety Cabinet Class Ii A2 Yr0090-a ?
Tous les équipements Kalstein sont garantis 1 an contre les défauts de fabrication. La garantie ne couvre pas les dommages dus à une mauvaise installation ou utilisation. Consultez nos «conditions générales» AQUI.
Puis-je demander un devis en ligne de Biosafety Cabinet Class Ii A2 Yr0090-a ?
Oui, vous pouvez demander un devis directement sur notre site officiel. Cliquez AQUI.