Biological Safety Cabinet YR06541: Ensuring Quality Control
The YR06541 Biological Safety Cabinet is a cutting-edge solution designed to protect personnel, products, and the environment. With a negative pressure system that prevents leaks, it employs a principle of 70% internal circulation and 30% external discharge. The cabinet's structure is made from high-quality cold-rolled steel, and the work surface is crafted from a corrosion-resistant physical-chemical plate. Precision laser cutting and electrostatic epoxy resin surface treatment ensure durability.
Product Description
This safety cabinet features intelligent control with an LCD touch panel for intuitive understanding. It complies with international standard ISO 14644.1 Class 5, equivalent to US Federal 209E Class 100. The cabinet is powered by a high-volume, energy-efficient German EBM motor, optimized to reduce turbulence concentration and ensure uniform airflow. With high-efficiency external HEPA filters and ultra-high-efficiency ULPA down-flow filters, the YR06541 maintains a high level of air quality.
| Feature | YR06541 | YR06542 |
|---|---|---|
| External Size (mm) | 1500 x 760 x 2250 | 1800 x 760 x 2250 |
| Internal Size (mm) | 1340 x 600 x 600 | 1640 x 600 x 600 |
| Weight (kg) | 330 | Variable |
| Filtration System | HEPA and ULPA | HEPA and ULPA |
| Airflow Type | 70% recirculation, 30% exhaust | 70% recirculation, 30% exhaust |
| Power Supply | 220V/50HZ | 220V/50HZ |
Market Price
The market price of the YR06541 Biological Safety Cabinet is approximately $2345.00. This competitive pricing reflects the advanced technology and materials used in its construction, making it a valuable investment for laboratories needing to adhere to strict safety and quality control standards. The price may vary based on additional features or configurations selected.
Frequently Asked Questions
What is the difference between ULPA and HEPA filters?
The ULPA filters used in the YR06541 provide ultra-high efficiency, capturing 99.999% of particles, while HEPA filters achieve 99.995% efficiency. Both types of filters are excellent, but ULPA filters offer a slightly higher level of purity.
What is the accuracy of the down-flow air control?
The down-flow air control accuracy is 0.015 m/s, ensuring uniformity and stability of airflow to maintain sterility within the work area.
What sizes are available for the YR06541 model?
The YR06541 model is available in a package size of 190 x 100 x 140 mm and an external size of 1500 x 760 x 2250 mm.
What level of cleanliness does the cabinet guarantee?
The cabinet guarantees Level 5 cleanliness according to international standard ISO 14644.1 (equivalent to US Federal 209E Class 100), which is a strict requirement for sensitive environments.
What are the advantages of using the YR06541 cabinet?
Advantages include dual filtration for high efficiency, superior safety with negative pressure design to prevent leaks, an optimized design for uniform airflow, and a durable construction that ensures longevity under regular use.
Are there any environmental requirements to operate this cabinet?
Yes, the working environment must be maintained between 10-30°C with relative humidity below 70% for optimal performance.
Pros and Cons
Pros:
- Dual Filtration: Utilizes external HEPA filters and ULPA/HEPA down-flow filters, ensuring up to 99.999% efficiency.
- Superior Safety: The negative pressure design prevents leaks, protecting the operator and the environment.
- Optimized Design: Reasonable air duct design and optimized negative pressure box for airflow uniformity.
- High-Performance German Motor: Employs low-energy, high-volume EBM motor.
- Durable Construction: Made from corrosion-resistant cold-rolled steel treated with epoxy resin.
Cons:
- Environmental Requirements: The working environment must be maintained between 10-30°C and humidity below 70%.
- Shipping Weight: The shipping weight is substantial, ranging from 138 kg to 198 kg depending on size, complicating transport and installation.
- Flow Limitations: Although 70% is recirculated, the 30% external discharge requires consideration of an escape ventilation system.
Field Usage
The Class II Type A2 Biological Safety Cabinet is essential for handling biological agents with low to moderate risk, such as viruses, bacteria, and cell cultures that require biosecurity. It is the standard choice in microbiology laboratories, hospitals, biotechnology, and pharmaceutical research centers where the protection of the product, personnel, and environment is critical. Its vibration control capability (average peak: 3μm) and stable airflow are vital for sensitive experiments.
Recommendations
To ensure longevity and maximum safety, it is recommended to regularly maintain the filters and check the calibration of the imported sensor. Confirm that the working environment meets the temperature (10-30°C) and humidity (below 70%) requirements. Periodically check the inlet airflow speed (average of 0.53m/s to 0.56m/s) and the down-flow air speed (average of 0.35m/s) to ensure that negative pressure protection remains effective. Use heavy-duty mobile wheels for initial positioning and ensure stability before operation.
If you are interested in exploring the YR06541 Biological Safety Cabinet further or wish to request a quote, please reach out to Kalstein Plus for more information.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.